vfcplmumbai@vimalfire.com +91-22-42010101 / +91-22-25783335
logo
  • ABOUT US
    • Corporate Film
    • Awards
    • CSR Policy
    • The Most Reliable Fire And Safety Service Providers
  • Applications
  • Products & Solutions
    • Products
    • Industry
    • Approval & Certifications
    • Divisions
    • Alliances
      • Fire Fighting Equipment

      • ● SHOOTFIRE 10500 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE 4000 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE 2000 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE 1000 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE Aluminium Alloy Water Monitor
      • ● SHOOTFIRE Aluminium Water Cum Foam Monitor
      • ● Fire Fighting Robot
      • Fire Detection System

      • ● SMARTAUGE Video based Fire Detection System
      • ● LIST - Sensor Based Linear Heat Detection System
      • ● dLIST - Sensor Based Linear Heat Detection System
      • ● ASD-Aspirating Smoke Detection System
      • ● ADW-Line Type Heat Detection System
      • ● Wireless Gas Detection System
      • Fire Supression System

      • ● SHOOTFIRE Gas Based Suppression System (Fixed Clean Agent Gas based Fire Suppression System)
        •  - CO2 Gas
        •  - Novec 1230
        •  - HFC 227ea (FM 200)
      • ● Inergen (IG-541) & Argonite (IG-55)
      • ● ISI & EN Marked SHOOTFIRE Aluminium Body Fire Extinguishers
      • ● ISI & EN Marked SHOOTFIRE MS Body Fire Extinguishers
      • ● Oxygen Reduction Fire Prevention System
      • Specialised Systems

      • ● SHOOTFIRE Rim Seal Fire Protection System
      • ● Video Based Security & Surveillance Solutions
      • ● Crash Fire Tenders
      • ● Smart Modular Consoles
      • ● Fire Detection & Suppression System (FDSS) and Fire Detection & Alarm System (FDAS)
      • ● Unmanned Aerial Vehicle
      • ● Nitrogen Injection Fire Protection System (NIFPS) for Transformers
      • ● Oil & Gas
      • ● Aviation
      • ● Energy
      • ● Mining
      • ● Manufacturing Plants
      • ● Defence
      • ● Railways
      • ● Shipping
      • ● Highway & Transportation
      • ● Pharmaceutical and Chemicals
      • ● Commercial & Consumers Solution
      • ● Power Plants
      • ● IOCL - Rim Seal Fire Protection System Certifications
      • ● HPCL - Rim Seal Fire Protection System Certifications
      • ● BPCL - Rim Seal Fire Protection System Certifications
      • ● IOCL - Foam Monitors Certifications
      • ● HPCL - Foam Monitors Certifications
      • ● BPCL - Foam Monitors Certifications
      • ● ONGC - Rim Seal Fire Protection System Certifications
      • ● ONGC - Foam Monitors Certifications
      • ● Fire Protection System
      • ● Fire Fighting Equipment
      • ● Fire Fighting Vehicles
      • ● Fire Exitnguisihers
      • ● Fire Fighting Chemicals
      • ● Fire Fighting Accessories
      • ● Protective Clothing
      • ● Safety & Rescue Equipment
      • ● Charter Hire / Fire Fighting Services
      • ● Video Based Security & Surveillance Solutions
      • ● Other Vehicles
      • ● Occupational Safety & Health
    •  

  • Downloads
  • Contact Us

Solutions / Products

Home   / LIST (SEC-20) – SENSOR BASED LINEAR HEAT DETECTION SYSTEM

LIST (SEC-20) – SENSOR BASED LINEAR HEAT DETECTION SYSTEM


Previous Next


  • About Product
  • Technical Specifications
  • Approvals
  • Downloads

LIST (SEC-20) – SENSOR BASED LINEAR HEAT DETECTION SYSTEM



Dust, heat, smoke, exhaust fumes and other interference factors have a significant impact on detecting fires when using conventional fire detectors. However, it is exactly under such difficult conditions that the fire risk is so great and it is vital to ensure quick and reliable detection – such as in tunnels, industrial facilities, power plants and car parks.

The SecuriSens LIST (VdS approved) line-type heat detectors from Securiton enable the rapid localisation/detection of a fire – even when used in harsh, aggressive environments. The SecuriSens LIST system with SEC 20 sensor cable is primarily used in industrial facilities and when monitoring smaller areas.

SecuriSens LIST detects incipient fires in record time. The sensor cable contains highly sensitive addressed sensors (spaced at intervals of 1m to 10m) whose response behaviour can be programmed individually. The sensor spacing in the cable can also be selected individually, to set up a monitoring system that is tailored exactly to the specific risk profile of the object. One can then profit from extremely precise, rapid and reliable fire detection.

Every second counts when reacting to an emergency, which is why these systems have transparent communication without any friction losses. The SecuriSens LIST systems also open up interesting options in terms of dimensioning – several cable terminal processors can be networked with one central master for remote control. The functionality of all sensors (at an interval of 10s) is permanently checked by the cable terminal processor so that uninterrupted monitoring of the object is ensured.

The spacing between sensors can be freely selected and the location of the sensors are determined according to the markings on the outer sheathing of the sensor cable. External individual sensors in metal housings are available for special applications and can be easily connected to the SecuriSens LIST system. The system offers reliable monitoring of sections of up to 3200 metres in length, or up to 320 sensors.


Features:
  • Sensor Spacing: 1 / 2 / 3 / 4 / 5m                                                              
  • Measurement Temp. Range: -40°C to +120°C     
  • Resolution (Measurement reading): 0.1°C                                                                                             
  • Operating Temp. Range:
    • Continuous: -40°C to +85°C/Short: up to max. meas. Temperature
  • Cable Diameter: 15mm - Facilitates easy routing through ducts                                                
  • Min. Bending Radius: 25cm - Greater Flexibility inlaying                                                                 
  • Max. Number of Sensors: (2x99)         
  • Sensor Type: Embedded, linearized, pre-calibrated semiconductor
  • Certification: EN54-5 (Classes A1 and A2), ATEX

Applications:
  • Escalators
  • Conveyor Belts
  • Road/Rail Tunnels
  • Ventilation Systems
  • Air Handling Units
  • Cable Ducts
  • Cable Galleries
  • Cold Storages
  • Car Parks
  • And More

Video


LIST - Sensor Based Linear Heat Detection System - Technical Specification



for more details


Downloads


LIST - Sensor Based Linear Heat Detection System

Featured Products

  • 10500 USGPM UL-Listed Foam Monitor
  • Aluminium Alloy Water Monitor
  • SMARTAUGE Video based Fire Detection System
  • ISI-Marked Aluminium Body Fire Extinguishers
  • Fire Fighting Robot
  • LIST - Sensor Based Linear Heat Detection System

Enquiry Form

Contact Us

Corporate Office

19/20, Vardhman Complex, Behind Punjab & Sind Bank, Opp Home Town, LBS Marg, Vikhroli West, Mumbai - 400083, Maharashtra, India.

Mail Us

vfcplmumbai@vimalfire.com

Call Us

+91-22-42010101 / +91-22-25783335

Follow Us

Connect with us

© Copyright 2021 Vimal Fire. All Rights Reserved. Developed by NWDCo

  • INFORMATION CENTRE
  • CLIENTELE
  • CERTIFICATIONS & APPROVALS
  • OUR REGISTERED PARTNERS